Sample — illustrative data

Sample test results

This is the exact format Volts clients receive at job closeout, with invented sample data. A real packet carries your job's actual test results, cable IDs, and locations — nothing is renamed or cleaned up after the fact.

1. Test results (Ethernet cable)

Cable IDFrom → ToLengthWire mapNEXT marginResult
SAMPLE-MDF-001PP1-01 → WO-10142 mPass+7.8 dBPASS
SAMPLE-MDF-002PP1-02 → WO-10238 mPass+8.4 dBPASS
SAMPLE-MDF-014PP1-14 → AP-CEIL-0355 mPass+6.9 dBPASS
SAMPLE-MDF-015PP1-15 → WO-11561 mPass-1.4 dBFAIL
SAMPLE-MDF-015RPP1-15 → WO-115, re-terminated61 mPass+4.6 dBPASS

This sample shows one marginal run (SAMPLE-MDF-015) and its retest after re-termination (SAMPLE-MDF-015R). The real packet attaches tester PDFs for every drop. Fiber runs include OTDR traces and insertion-loss results per strand.

2. Port map and label list

Every cable ID on the report matches the printed label at both ends and the port-map row — so your IT team, or the next contractor, can find any run in minutes without a toner. The schedule lists closet, panel, port, work-area outlet, and served device for each ID above.

3. Photos of the finished work

Dated photos of each closet before covers go on: dressed bundles, labeled patch fields, and pathway. Published client job photos on our site are used only with written permission.

Get this for your building — free site walk

Questions about the format? Call (402) 992-2316.